RoyalTek REB-3000 User Manual
Page 30
RoyalTek RGM-3000/REB-3000
GPS Module Operational Manual)
25
Binary(Hex)
Name
Bytes
Scale Example
Units
Description
Message ID
1
88
ASCII 136
3D Mode
1
01
1 (always true=1)
Alt Constraint
1
01
YES = 1,NO = 0
Degraded Mode
1
01
See Table C-7
TBD 1
01
Reserved
DR Mode
1
01
YES = 1,NO = 0
Altitude
2
0000
Meters Range –1,000 to 10,000
Alt Hold Mode
1
00
Auto = 0,Always=1,Disable=2
Alt Source
1
02
Last Computed=0,Fixed to=1
Coast Time Out
1
14
Seconds 0 to 120
Degraded Time
Out
1
05
Seconds 0 to 120
Dr Time Out
1
01
Seconds 0 to 120
Track Smoothing
1
01
YES = 1,NO = 0
Payload Length:14 bytes
Table 25
Degraded Mode Byte Value
Byte Value
Description
0
Use Direction then Clock Hold
1
Use Clock then Direction Hold
2 Direction(Curb)Hold
Only
3 Clock(Time)Hold
Only
4
Disable Degraded Modes
DOP Mask Control – Message I.D. 137
Table 26 contains the input values for the
following example:
Auto Pdop/Hdop, Gdop =
8(default),Pdop=8,Hdop=8
Example:
A0A20005 – Start Sequence and Payload
Length
8900080808 – Payload
00A1B0B3 – Message Checksum and
End Sequence
Table 26
DOP Mask Control
Binary(Hex)
Name
Bytes
Scale Example
Units
Description
Message ID
1
88
ASCII 137
DOP Selection
1
00
See Table 25
GDOP Value
1
08
Range 1 to 50
PDOP Value
1
08
Range 1 to 50
HDOP Value
1
08
Range 1 to 50
Payload Length: 5 bytes
Table 27
DOP Selection
Byte Value
Description
0 Auto
PDOP/HDOP
1 PDOP
2 HDOP
3 GDOP
4
Do Not Use
DGPS Control – Message I.D.138
Table 28 contains the input values for the
following example:
Set DGPS to exclusive with a time out of
30 seconds.
Example: