beautypg.com

Maintenance, Removing valve – Regency P121 User Manual

Page 38

background image

Regency

®

P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

38

12) Lift the entire assembly out.

8) Remove the Side Base Brick Panels and

fi nally the Long Base Brick Panels.

MAINTENANCE

Remove Left & Right Side Base

Brick Panels

Remove the 2 Long Base Brick Panels

9) Disconnect the inlet gas line.

10) Disconnect the 2 TP wires and the 2 TH

wires from the valve.

11) Remove the 16 Phillips head screws

securing the valve tray.

13) Undo the pilot tube from the valve with a
7/16"

wrench.

14) Undo the quick drop out thermocouple nut

on the valve with a 9mm (metric) wrench.

15) Remove the Piezo igniter wire and push

button assembly.

16) Undo the "gas out" fl are nut with a 13/16"

wrench.

17) Undo the "gas out" fl are fi tting with an
11/16"

wrench.

18) Remove the 6 Phillips head screws from

the sides of the valve bracket and remove
valve.

Hint:

If you are using black pipe, ensure
that there is a union by the valve,
otherwise removal will be almost
impossible.

REMOVING VALVE

1) Shut off the gas supply.

2) Remove the louvers and trim kit. Remove

the front door.

3) Remove the logs, embers.

4) Remove the grate by lifting straight up.

7) Slide the burner assembly away from the

orifi ce and lift out.

5) Remove the side brick clip in the top of the

fi rebox and then slide the Side Brick Panel
out. The brick panels are very fragile
- handle with care.

6) Remove the burner by removing the 4

screws.