beautypg.com

Installation, Rigid pipe venting systems, Horizontal or vertical terminations – Regency P121 User Manual

Page 17

background image

Regency

®

P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

17

Pipe Length

Vertical

Terminal

Storm Collar

Part # 953

Flashing

943 or 943S

Ceiling Firestop

(Part # 963)

Pipe

Length

Adj.Pipe Length

11" - 14-5/8"

90 Elbow

o

Horiz

Termina
Part# 94

Wall Thimble

(Part # 942)

(Required in

Canada)

Vinyl Siding

Standoff (Optional)

(Part #950)

Rigid Pipe Adapter

(Part #510-994)

45 Elbow

o

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

The minimum components required for a basic horizontal
termination are:

1 Simpson

Duravent

Adaptor

1 Horizontal

Termination

Cap

1 45

o

Elbow

1 Rigid

Pipe

Adaptor

1 Wall

Thimble

1 Length of pipe to suit wall thickness
(see

chart)

Wall thickness is measured from the back standoffs to the inside
mounting surface of termination cap. For siding other than vinyl furring
strips may be used, instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding),
measure to outside surface of wall without siding and add 2 inches.

INSTALLATION

Flat Wall Installation

Wall Thickness Vent Length

(inches) Required (inches)

4"

-

5-1/2"

6"

7"

-

8-1/2"

9"

10"

-

11-1/2"

12"

9"

-

14-1/2" 11" - 14-5/8" Adj. Pipe

15"

-

23-1/2"

17" - 24" Adj. Pipe

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

The FPI AstroCap

TM

and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent GS,

American Metal Products Ameri Vent Direct Vent, Security Secure Vent

®

, Selkirk Direct-Temp. AstroCap

TM

is a proprietary trademark of FPI Fireplace

Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Duravent Direct-Vent GS, Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.

WARNING:

Do not combine venting components from
different venting systems.

However use of the the AstroCap

TM

and FPI

Riser is acceptable with all systems.

This manual is related to the following products: