beautypg.com

Installation – Regency P121 User Manual

Page 27

background image

Regency

®

P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

27

24) Locate the ground lug at the receptical

box, left of the unit.

Installer Notice:

These instructions must be left

with the appliance.

25) Connect one end of the supplied green

ground wire to the lug with the nut and
washer from the kit.

26) Install the 1/2" bushing to the heat shield.

Ground

wire from

kit

28) Plug the DC spark generator wires to the

DC Sparker.

29) Connect the ground wire to the DC

Sparker mounting bracket.

31) Mount the heat shield to the DC Sparker.

Secure into place with the velcro, which is
provided in the kit.

33) Tie up the loose wire with the wire clip.

Heat Shield

27) Run the other end of the ground wire and

DC spark generator wires through the
bushing on the heat shield.

32) Find a location which is not too hot and is

easy to reach for changing the

battery.

34) Check for gas leaks.

35) Check inlet and outlet pressures.

36) Check operation of fl ame control.

37) Check for proper fl ame appearance and

glow on logs.

30) Install the supplied battery into the DC Sparker

Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box

will need to be replaced annually.

Battery

Compartment

INSTALLATION

This manual is related to the following products: