17) Reverse steps 4) to 1).

18) Attach the label "This unit has been

converted to LPG" near or on top of the
serial # decal.

19) Replace yellow "NG" label with red "LPG"

label.

WARNING!

Do not over tighten the screw.

Recommended to

grip the wrench by the short side.

11) Insert a 5/32” or 4mm Allen wrench into

the hexagonal key-way of the screw
(Fig. 2), rotate it counter-clockwise until it
is free and extract it.

12) Check that the screw is clean and if

necessary remove dirt.

13) Flip the screw (Fig. 3).

14) Using the Allen wrench as shown in Fig.4,

rotate the screw clockwise until snug, do
not overtighten.

Fig.2

Fig.4

15) Verify that if the conversion is from NG

to LPG, the screw must be re-assembled
with the red o-ring visible (Fig. 5).

16) Re-assemble the black protection cap

(Fig. 6).

WARNING!

Also check that the pilot and

main burner injectors are

appropriate for the gas type.

LPG Configuration

Red o-ring visible

Fig.5

Fig. 6

Installation of the DC Sparker:

20) Locate the Piezo Ignitor situated at the

side of valve.

21) Remove the Piezo Ignitor by unscrewing

the nut at the back of the mounting
bracket.

22) Disconnect the ignitor wire from the Piezo

Ignitor and connect it to the D.C. Sparker.

Piezo

Ignitor

Ignitor

Wire

Piezo

Ignitor

Ignitor

Wire

DC

Sparker

23) Connect the DC spark generator wires

to the SIT Valve with the screw, which is
provided in the kit.