beautypg.com

8 absolute maximum ratings, 9 recommended operating conditions, Overview – Renesas M3A-HS60 User Manual

Page 13

background image

Overview

1.8 Absolute Maximum Ratings

Rev.1.00 June 1,2005

1-9

REJ11J0002-0100Z

1

1.8 Absolute Maximum Ratings

Table1.8.1 lists the absolute maximum ratings of M3A-HS60.

Table1.8.1 Absolute Maximum Ratings of M3A-HS60

Symbol Parameter

Rated

Value

Remarks

VCC

5V System Power Supply Voltage

-0.3V to 6.0V

Relative to VSS

3VCC

3.3V System Power Supply Voltage

-0.3V to 4.6V

Relative to VSS

1.2VCC

1.25V System Power Supply Voltage

-0.3V to 1.7V

Relative to VSS

Topr

Operating Ambient Temperature

-5°C to 55°C

No dewdrops allowed.

Use in corrosive gas environment prohibited.

Tstr

Storage Ambient Temperature

-10°C to 60°C

No dewdrops allowed.

Use in corrosive gas environment prohibited.

Note: The ambient temperature refers to the air temperature in the closest place from the board.

1.9 Recommended Operating Conditions

Table1.9.1 lists the recommended operating conditions of the M3A-HS60.

Table1.9.1 Recommended Operating Conditions of M3A-HS60

Symbol Parameter Rated

Value

Remarks

VCC

5V System Power Supply Voltage

4.75V to 5.25V

Relative to VSS

3VCC

3.3V System Power Supply Voltage

3.0V to 3.6V

Relative to VSS

(Normally supplied from regulator)

1.2VCC

1.25V System Power Supply Voltage

1.15V to 1.35V

Relative to VSS

(Normally supplied from regulator)

Maximum Power Consumption in the Board

Within 1A

Topr

Operating Ambient Temperature

5°C to 50°C

No dewdrops allowed.

Use in corrosive gas environment prohibited.