8 absolute maximum ratings, 9 recommended operating conditions, Overview – Renesas M3A-HS60 User Manual
Page 13
Overview
1.8 Absolute Maximum Ratings
Rev.1.00 June 1,2005
1-9
REJ11J0002-0100Z
1
1.8 Absolute Maximum Ratings
Table1.8.1 lists the absolute maximum ratings of M3A-HS60.
Table1.8.1 Absolute Maximum Ratings of M3A-HS60
Symbol Parameter
Rated
Value
Remarks
VCC
5V System Power Supply Voltage
-0.3V to 6.0V
Relative to VSS
3VCC
3.3V System Power Supply Voltage
-0.3V to 4.6V
Relative to VSS
1.2VCC
1.25V System Power Supply Voltage
-0.3V to 1.7V
Relative to VSS
Topr
Operating Ambient Temperature
-5°C to 55°C
No dewdrops allowed.
Use in corrosive gas environment prohibited.
Tstr
Storage Ambient Temperature
-10°C to 60°C
No dewdrops allowed.
Use in corrosive gas environment prohibited.
Note: The ambient temperature refers to the air temperature in the closest place from the board.
1.9 Recommended Operating Conditions
Table1.9.1 lists the recommended operating conditions of the M3A-HS60.
Table1.9.1 Recommended Operating Conditions of M3A-HS60
Symbol Parameter Rated
Value
Remarks
VCC
5V System Power Supply Voltage
4.75V to 5.25V
Relative to VSS
3VCC
3.3V System Power Supply Voltage
3.0V to 3.6V
Relative to VSS
(Normally supplied from regulator)
1.2VCC
1.25V System Power Supply Voltage
1.15V to 1.35V
Relative to VSS
(Normally supplied from regulator)
–
Maximum Power Consumption in the Board
Within 1A
Topr
Operating Ambient Temperature
5°C to 50°C
No dewdrops allowed.
Use in corrosive gas environment prohibited.