beautypg.com

NEC NX7700i/5040H-32 User Manual

Page 86

background image

Base Module

855-900547-200 2-50

cmd arg1 arg2 arg3 arg4

Description

cellx

n m -

Attach the CELL Card having physical CELL
number x to partition number n, using logical
CELL number m (which is visible to the
software or BIOS).
This command may also be used to change
a logical CELL number for an already
attached CELL.
A logical CELL number must be unique to
every 8 CELL Cards.
The logical CELL number of an online CELL
Card is unable to be altered.

ioxx

n m [p|s]

Attach the IOX Card having physical IOX
number x to partition number n, using logical
IOX number m (which is visible to the
software or BIOS).
Specify p for arg4 if the PCI Bay with BIO is
to use that BIO. Specify s for arg4 if the PCI
Bay having duplicated BIOs is to use the
secondary BIO.
This command may also be used to change
a logical IOX number for an already attached
IOX.
A logical IOX number must be unique within
a partition.
The logical IOX number of an online IOX
Card cannot be altered.

-

-

-

-

Use this command to detach partition
numbers from CELL or IOX Cards.
If no argument is specified or an argument
has an error, the detach command help
opens.
Online components are unable to be
detached.
It is not allowed to detach components either
when the partition is booting up, shutting
down, or handing an error.

cellx

-

-

-

Detach the CELL Card with physical CELL
number x from the partition to which it is
currently attached.

ioxx

-

-

-

Detach the IOX Card with physical IOX
number x from the partition to which it is
currently attached.

detach

partx

-

-

-

Detach all the CELL and IOX Cards from the
partitions to which they are currently
attached.
x: Partition number

This manual is related to the following products: