Triggers digital trigger, Power requirement, Physical – National Instruments E Series User Manual
Page 95: Environment
Appendix A Specifications for DAQCard-AI-16XE-50
DAQCard E Series User Manual
A-12
National Instruments Corporation
DMA modes ...................................... Single transfer, demand transfer
Triggers
Digital Trigger
Compatibility .................................... TTL
Response ........................................... Rising or falling edge
Pulse width........................................ 10 ns min
Power Requirement
+5 VDC (
±
5%) .................................. 230 mA active,
90 mA standby
Power available at I/O connector....... +4.65 to +5.25 VDC
at 250 mA
Note:
You can save current by using the NI-DAQ power down utility when your
DAQCard is not in use.
Physical
PC Card type ..................................... Type II
I/O connector .................................... PCMCIA 68-position female
connector
Environment
Operating temperature ....................... 0
°
to 55
°
C
Storage temperature........................... -55
°
to 150
°
C
Relative humidity .............................. 5% to 90% noncondensing