beautypg.com

Physical, Environment – National Instruments E Series User Manual

Page 90

background image

Appendix A Specifications for DAQCard-AI-16E-4

National Instruments Corporation

A-7

DAQCard E Series User Manual

Note:

These power usage figures do not include the power used by external
devices that are connected to the fused supply present on the I/O connector.

Note also that under ordinary operation, the DAQCard has a current
requirement of 270–290 mA; but if the analog inputs being sampled are
overdriven at high gains, or if the analog inputs are left floating when the
DAQCard is not in use, the current may increase to 400 mA.

You can save current by using the NI-DAQ power down utility when your
DAQCard is not in use.

Physical

PC Card type ..................................... Type II

I/O connector .................................... PCMCIA 68-position female

connector

Environment

Operating temperature ....................... 0

°

to 55

°

C

Storage temperature........................... -55

°

to 150

°

C

Relative humidity .............................. 5% to 90% noncondensing