beautypg.com

Mode 1 output timing, Mode 1 output timing -28, Figure 4-14 – National Instruments 6023E User Manual

Page 58

background image

Chapter 4

Signal Connections

6023E/6024E/6025E User Manual

4-28

ni.com

Mode 1 Output Timing

Timing specifications for an output transfer in mode 1 are shown in
Figure 4-14.

Figure 4-14. Timing Specifications for Mode 1 Output Transfer

Name

Description

Minimum

Maximum

T1

WR* = 0 to INTR = 0

250

T2

WR* = 1 to Output

200

T3

WR* = 1 to OBF* = 0

150

T4

ACK* = 0 to OBF* = 1

150

T5

ACK* Pulse Width

100

T6

ACK* = 1 to INTR = 1

150

All timing values are in nanoseconds.

WR*

OBF*

INTR

ACK*

DATA

T1

T2

T3

T4

T5

T6

This manual is related to the following products: