beautypg.com

Figure 3-30. leading edge output state machine – National Instruments 653X User Manual

Page 84

background image

Chapter 3

Timing Diagrams

© National Instruments Corporation

3-33

653X User Manual

Figure 3-30. Leading Edge Output State Machine

Wait

For

Data

Wait

For

REQ

Programmable

Delay

Programmable

Delay

Wait

For

REQ

When REQ

Asserted

Clear

ACK

Pulse

When REQ

Unasserted

Initial State: ACK Cleared

When 653

X Device has

data to output, output data.*

Send

ACK

Pulse

* With REQ-edge latching enabled, the data output is

delayed until the next inactive-going REQ edge.