background image

Chapter 2

Using Your 653X

653X User Manual

2-16

ni.com

Figure 2-7. Programming Handshaking Output in LabVIEW/LabVIEW RT

By default, for output buffered transfers the 6534 device will preload the on
board memory with data before starting the output operation. This is done
to eliminate or reduce the impact of the PCI bus bandwidth limitations and
increase the overall transfer rate.

DIO Start VI

DIO Parameter VI

DIO Clear VI

Buffered

Operation?

DIO Config VI

Yes

Burst

Mode?

No

No

No

Reverse

PCLK

Direction?

Yes

Yes

Finite

Buffer?

DIO Wait VI

Yes

Done?

DIO Write VI

Yes

No

No

DIO Write VI

Digital Single

Write VI

No

Reverse

PCLK

Direction?

Yes

DIO Parameter VI

Digital Group

Config VI

Resets the lines

to default states.

Digital Group

Config VI