ni.com

Figure 3-7. Burst Input Timing Diagram (PCLK Reversed)

Parameter

Description

Minimum

Maximum

Input Parameters

t

pc

PCLK cycle time

50

t

pw

PCLK high pulse duration

20

t

pl

PCLK low pulse duration

20

t

rs

Setup time from REQ valid to PCLK falling
edge

1

t

rh

Hold time from PCLK to REQ invalid

0

t

dis

Setup time from input data valid to PCLK
falling edge

0

t

dih

Hold time from PCLK to input data valid

0

Output Parameters

t

pa

PCLK to ACK valid

22

t

ah

Hold time from PCLK to ACK invalid

3

All timing values are in nanoseconds.

PCLK

ACK

Data In Valid

REQ

t

dis

t

dih

t

rs

t

pa

t

pw

t

pl

t

pc

t

rh

t

ah