Chapter 3

Timing Diagrams

653X User Manual

3-26

ni.com

Figure 3-22. Trailing Edge Input Timing Diagram

Note

When REQ-edge latching is enabled (default), the REQ edge determines when data

will be latched. Input data valid needs to be held t

r*di

after the trailing edge of REQ occurs.

When REQ-edge latching is disabled, input data valid needs to be held t

adi

after the active

going edge of the ACK signal occurs.

Parameter

Description

Minimum

Maximum

Input Parameters

t

rr*

REQ pulse width

75

t

r*r

REQ inactive duration

75

t

dir*

Input data setup to REQ inactive
(with REQ-edge latching)

0

t

r*di

Input data hold from REQ inactive
(with REQ-edge latching)

10

t

dir

Input data setup to REQ
(with REQ-edge latching disabled)

0

t

adi

Input data hold from ACK
(with REQ-edge latching disabled)

0

Output Parameters

t

aa*

ACK pulse width

225

1

275

2

t

a*r*

ACK inactive to next REQ inactive

0

1

t

aa*

(min.)

= 225 + programmable delay

2

t

aa*

(max) = 275 + programmable delay

REQ

Input Data Valid

(REQ-edge

latching)

Input Data Valid

(REQ-edge

latching disabled)

t

dir*

t

r*r

t

dir

t

aa*

t

a*r*

t

rr*

t

r*di

ACK

t

adi

ACK and REQ are shown as active high