Serial Communications

Planar PD7170 Installation/Operation Manual

73

PREL

IMINA

RY

Table 6-2 lists the valid operations commands. For all but Execute functions, the

response from the projector is the command and “= ” where is

the current value or “NA” if the value is not available. For Execute functions the

response is the same command. All responses are in UPPERCASE.

Some operations command examples:

Input: op bright ? [CR]
Response: OP BRIGHT = 100 [CR]
Input: op bright + [CR]
Response: OP BRIGHT = 101 [CR]
Input: op bright = 127 [CR]
Response: OP BRIGHT = 127 [CR]
Input: op bright - [CR]
Response: OP BRIGHT = 126 [CR]
Input: op resync [CR]
Response: OP RESYNC [CR]
Input: op sharp.mode = 1 [CR]
Response: OP SHARP.MODE = 1 [CR]
Input: op sharp.simple = 50 [CR]
Response: OP SHARP.SIMPLE = NA [CR]
Input: op sharp.simple ? [CR]
Response: OP SHARP.SIMPLE = NA [CR]
The last three commands show what happens when a control is grayed out. In

this case, the sharpness mode was set to advanced (value = 1) and then the

simple sharpness slider was attempted to be adjusted and queried. The

response was “NA” or not available.

Table 6-2. Serial Commands

Operation

Commands

Values

Notes

aspect

= ?

0 = 16:9
1 = Letterbox

2 = 4:3

3 = 4:3 Narrow
4 = Native

memory

= ?

0 = User Memory 1

1 = User Memory 2
2 = ISF Day

3 = ISF Night

4 = Default

? only returns a value if

ISF Day or ISF Night is
active, otherwise it

returns NA

save.mem

=

0 = User Memory 1
1 = User Memory 2