5.1

Lamp Replacement

The lamp should be replaced when it reaches the end of its life (typically

between 2000 and 2500 hours depending on the Lamp Power setting), or

sooner if a noticeable degradation in brightness occurs. Contact your Planar

dealer to obtain a replacement lamp.
1. Turn off the projector and unplug the power cord. Allow the projector to

cool down for approximately 60 minutes prior to removing the lamp

assembly for replacement.

2. Using a flat-blade screwdriver,

loosen the four screws holding the

rear compartment cover in place.

3. Remove the rear compartment

cover by tilting it upward.

4. Loosen the screw on the lamp

cover and pull the lamp cover

out.

5. Loosen the two screws on the

lamp module.

6. Pull the lamp module handle

firmly to remove the lamp

module.

7. Perform Steps 6 through 2 (in

reverse order) to install the new

lamp module.

8. Turn on the power and reset the

lamp timer.

5.