System log – Paradyne Hotwire 6342 User Manual
Page 60

6. Diagnostics and Troubleshooting
6-2
May
2001
6371-A2-GB20-20
System Log
The router can log significant system events (SYSLOG). The SYSLOG can be
maintained locally on the router and can also be sent to a remote SYSLOG server,
preferably in the management domain.
To activate:
T
The router must be configured to enable the output of SYSLOG messages via
the
syslog enable
command.
The Management Controller Card (MCC) always has SYSLOG enabled.
T
An IP address (loopback or remote) must be supplied.
T
The SYSLOG can also be captured by a remote SYSLOG server running the
UNIX daemon syslogd or an equivalent program. It is necessary to know the
IP address where the syslogd resides and the UDP port number the syslogd is
using.
The advantage of using a remote SYSLOG server is that ALL events will be
maintained upon restart of the router. The local SYSLOG is cleared upon
restart.
Events are classified by severity level and the system administrator can specify the
minimum severity to be logged.
show syslog
Minimum Access Level: Operator
Command Mode: Standard
Shows whether the current status of system as enabled or disabled. The severity level,
management IP address, and User Datagram Protocol (UDP) port are displayed.
syslog {enabled | disabled}
level {emer | err | norm | info}
management ip-addr
x.x.x.x
port
nnn
syslog
{
enable
|
disable
}
Minimum Access Level: Administrator
Command Mode: Config
Enables or disables SYSLOG output. When enabling SYSLOG, the SYSLOG IP address
must be entered (next command) and saved.
enable – Enables SYSLOG output.
disable – Disables SYSLOG output so no system log entries are sent.
syslog ip
ip-addr
Minimum Access Level: Administrator
Command Mode: Config
Specifies the IP address of the device to receive system log entries.
ip-addr – The IP address for SYSLOG. The loopback address of 127.0.0.1 can be used to
have the functionality of the SYSLOG (entries kept locally).