beautypg.com

Printronix SL5000r MP User Manual

Page 69

background image

69

RFID MAX RETRY
Check System

Error Handling = Overstrike in
the RFID CONTROL menu,
and the Label Retry count has
been exhausted.

Press PAUSE to clear the
message.
See “Troubleshooting” on
page 70.

RFID TAG ERR:
Read-Only Tag

A write was attempted on a
read-only tag.

Press PAUSE to clear the
message.
Change media to writable
tags or remove the write
command from the
application.

RFID TAG FAILED
Check Media

Error Handling = Stop in the
RFID CONTROL menu, and
the RFID encoder could not
read the RFID tag.

Press PAUSE to clear the
message.
See “Troubleshooting” on
page 70.

RFID UNLOCK CMD:
Not Supported!

An unlock command was
executed on a tag which does
not support locking.

Press PAUSE to clear the
message.
Remove the unlock
command from the
application.

RFID ACS FIELD:
Not Supported!

The ACS field was accessed
on a tag which does not
support the ACS field.

Press PAUSE to clear the
message.
Remove references to the
ACS field from the
application.

RFID KIL FIELD:
Not Supported!

The KIL field was accessed
on a tag which does not
support the KIL field.

Press PAUSE to clear the
message.
Remove references to the
KIL field from the
application.

Table 3. Control Panel Error Messages

Error Message

Explanation

Solution