Network Interface Options Menu

For Network Interface Options, refer to Table A-2. To access the Network
Interface Options screen, follow this menu selection sequence:

Main Menu

Configuration (Load Configuration From)

Configuration Edit/Display

Network

Table A-2.

Network Interface Options

Network-initiated DSU Loopback (64K CC)

Possible Settings: Enable, Disable
Default Setting: Enable

Indicates whether the access unit responds to a DSU latching loopback sequence sent
by the network as specified by TR62310.

H

Network-initiated DSU Loopback (64K CC) option appears when

Operating Mode

is set to DDS in Table A-1.

Enable – Responds to network-initiated commands to start and stop a latching DSU
loopback.

Disable – DSU will not respond to a DSU loopback initiated by the network.

Data Scrambling (64K CC)

Possible Settings: Enable, Disable
Default Setting: Disable

Data scrambling is used to suppress the possible simulation of network-initiated DSU
latching loopback commands by application data.

H

Data Scrambling (64K CC) option appears when

Operating Mode

is set to DDS in

Table A-1.

Enable – Enables data scrambling. The local and remote units must be set the same.

Disable – No data scrambling.

V.54 Initiated DSU Loopback

Possible Settings: Enable, Disable
Default Setting: Disable

When enabled, user data is looped back to the network when a V.54 Loop Up sequence
is received. The DSU loopback ends when a V.54 Loop Down sequence is detected.

Enable – DSU loopback can be initiated or terminated by a remote unit sending in-band
V.54 Loop 2 Up or Down sequences.

Disable – V.54 Loop 2 sequences are ignored.