511 test pattern for the network – Paradyne 7510 DSU User Manual
Page 38
Testing
5-6
7510-A2-GB20-10
November 1997
511 Test Pattern for the Network
This test sends or monitors the 511 test pattern over the network interface.
"
Procedure
To run a Send 511 test:
1. Position the cursor at the Start command next to Send 511 on the Network
Tests screen.
2. Press Enter.
3. The Start command is changed to Stop. If you want to manually stop the test,
verify that the cursor is positioned at the Stop command.
4. Press Enter. The duration of the test is displayed.
"
Procedure
To run a Monitor 511 test:
1. Position the cursor at the Start command next to Monitor 511 on the Network
Tests screen.
2. If desired, use Ctrl-a to switch to the screen function key area and use the
virtual function key r or R (ResetMon) to clear the error counter to zero. Press
Ctrl-a to return the cursor to the Start command.
3. Press Enter.
4. The Start command is changed to Stop. If you want to manually stop the test,
verify that the cursor is positioned at the Stop command.
5. Press Enter. The duration of the test is displayed.
on page 5-3 for an example of the Network