Configuration Option Tables

A-3

7510-A2-GB20-10

November 1997

Table A-1.

System Options (2 of 2)

LADS Line Rate (Kbps)

Possible Settings: 56, 64
Default Setting: 64

Line operating rate for LADS operation.

H

LADS Line Rate (Kbps) option appears when Operating Mode is set to LADS.

56 – 56 kbps line rate. Provides increased distance for the LADS applications.

64 – 64 kbps line rate.

Test Timeout

Possible Settings: Enable, Disable
Default Setting: Enable

Allows user-initiated tests to end automatically. Recommend enabling when the unit is
managed remotely through the IMC to avoid the requirement to terminate the test
manually.

Enable – User-initiated loopback and pattern tests end when test duration is reached.

Disable – Tests must be terminated manually from the Network Tests screen. Refer to

Running Network Tests

in Chapter 5.

NOTE:

Tests commanded by the DTE or network-initiated tests are not affected by
this test timeout.

Test Duration (min)

Possible Settings: 1–120
Default Setting: 10

Number of minutes for a test to be active before automatically ending.

H

Test Duration (min) option appears when Test Timeout is enabled.

1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.