Paradyne 7510 DSU User Manual
Page 49
Configuration Option Tables
A-3
7510-A2-GB20-10
November 1997
Table A-1.
System Options (2 of 2)
LADS Line Rate (Kbps)
Possible Settings: 56, 64
Default Setting: 64
Line operating rate for LADS operation.
H
LADS Line Rate (Kbps) option appears when Operating Mode is set to LADS.
56 – 56 kbps line rate. Provides increased distance for the LADS applications.
64 – 64 kbps line rate.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows user-initiated tests to end automatically. Recommend enabling when the unit is
managed remotely through the IMC to avoid the requirement to terminate the test
manually.
Enable – User-initiated loopback and pattern tests end when test duration is reached.
Disable – Tests must be terminated manually from the Network Tests screen. Refer to
NOTE:
Tests commanded by the DTE or network-initiated tests are not affected by
this test timeout.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
H
Test Duration (min) option appears when Test Timeout is enabled.
1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.