Viewing network interface status – Paradyne 7510 DSU User Manual

Page 27

background image

Monitoring the DSU

4-6

7510-A2-GB20-10

November 1997

Viewing Network Interface Status

The network interface status fields are read-only:

H

Line Rate (Kbps). If the DSU is connected to an operating line and the Line
Rate (Kbps) shows Autobaud and does not change to a line rate within about
25 seconds, Line Rate (Kbps) may have to be reconfigured manually. Refer
to Table A-1,

System Options

.

H

Loop Loss (dB). The loop loss is the loss of signal strength of the receive
line signal from the local loop.

To view the Network Interface Status, follow this menu selection sequence:

Main Menu

Status

Network Interface Status

Table 4-5 describes the contents of the Network Interface Status screen.

Table 4-5.

Network Interface Status Screen Contents

Field

Status

What the Status Indicates

Line Rate (Kbps)

56 Kbps
64 CC
64 LADS

Line rate on the network interface.
Autobaud indicates the DSU is
trying to determine the network line

64 LADS
Autobaud

trying to determine the network line
rate. If this does not change to a
numeric value within about
25 seconds, you may need to set
the Line Rate manually

No Signal

the Line Rate manually.

No signal can be detected over the
network interface.

Loop Loss (dB)

0 to – 65 dB

Amount of loop loss – loss of signal
strength of the receive line signal
from the local loop, measured in
decibels.

Inoperative

The line may be disconnected.