Dataproducts parallel interface, Dataproducts interface connector pin assignments – Printronix L1524 User Manual
Page 120
B–4
Host I/O Interfaces
Dataproducts Parallel Interface
This interface allows the printer to operate with controllers designed for
Dataproducts printers. The interface is capable of transferring up to 500,000
characters per second. The maximum cable length from the controller (host
computer) to the printer is 40 feet.
NOTE: Optional adapter cable (p/n 703316–001) and termination resistors
RP1 330
Ω
(p/n 101381–331) and RP2 220
Ω
(p/n 101381–002) are
required.
Dataproducts Interface Connector Pin Assignments
The printer provides a 36–pin D–shell connector on the rear panel for connection
of a parallel interface cable. This 36–pin connector requires a cable adapter to
convert it to a 50–pin AMP connector for Dataproducts compatibility. Contact the
factory for the adapter (p/n 703316–001). Table B–2 lists the pin assignments of
the Dataproducts cable adapter.
Table B–2. Dataproducts Parallel Interface Pin Assignments (Cable Adapter)
Input Signals
Output Signals
Signal
Pin
Signal
Pin
DATA LINE 1
19
Return
3
READY/FAULT
22
Return
6
DATA LINE 2
20
Return
4
ON LINE/SELECT
21
Return
5
DATA LINE 3
1
Return
2
DATA REQUEST/ACK
23
Return
7
DATA LINE 5
34
Return
18
Interface Verif.
45, 46
DATA LINE 6
43
Return
42
PAPER INST
30
Return
14
DATA LINE 7
36
Return
35
DATA LINE 8
28
Return
44
DATA STROBE
38
Return
37