BUC Fault: PLL in Block UpConverter lock fail
The Modem is configured to operate with a Paradise BUCand the PLL generating the SHFcarrier in
U
TF
BM
(10M ref' to BUC: On)
the BUC has failed. The state of the reference feed to the BUC is also reported.
UNIT WARNINGS
(Top+Bottom lines of disp’)
Unit Warnings: Deferred alarm relay only
Warning: TX CARRIER IS MUTED as power
The Tx carrier is set to mute after a power fail. The power has failed and returned and the operator is
D
It is the carrier mute
outage, CARRIER: 1=Restore 2=Mute
offered the option to restore the Tx carrier status to ON. The Tx carrier is set under Change, Tx,
which causes the
Mod, Carrier
warning
Warning: Int' temp
This message refers to the internal unit temperature, Check the modem vent slots are clear and the
D
WILL MUTE outside operating range 0-60C
rear fan has not failed. This Tx Mute may be disabled, see Fault Mode = 8 in Appendix E
Warning: 10MHz Reference clk in failed,
The station clock, set to 10MHz, has been selected as the reference the Tx & Rx synthesisers, but it
D
IF & Clocks switched to int' 1PPM ref.
has failed. Check the signal applied to the station clock port.
Unit Warn: Turbo codec DLL fail ( This is an internal failure, consult the factory with the error code. Typically though it is caused by D code>) poor seating of the Turbo option board on the mating connectors.