Paradise P300 User Manual
Page 179
P300H
P300 Series Modem Installation and Operating Handbook
Page 179
APPENDIX B: MODEM CONNECTOR PINOUTS
REMOTE M&C (RS485/RS232) CONNECTOR
The selection of RS232 or RS485 must be made via the front panel. Refer to Appendix D for an overview
of the Remote M&C protocol.
Connector type: 9 Pin `D' Female, pin compatible with `SA-bus`
Pin
Direction
Signal
Name-
name
RS232
Name-RS485
SA Bus
Paradise
1
Shield/Gnd *
Shield
Shield/Gnd
Shield/Gnd
2
SRR
-
-
3
Master-B
+ to modem
SSD
RX-B
-
4
Slave-B
+ from modem
SRD
TX-B
-
5
Shield/Gnd *
SG
Shield/Gnd
Shield/Gnd
6
Slave-A
- from modem
RC
TX-A
Tx. data
7
SRS
-
-
8
SCS
-
-
9
Master-A
- to modem
SC
RX-A
Rx. data
* Pins 1 & 5 are both grounded on the modem (ie Shield and Ground are interchangeable).
See also the “M&C Appnote” available from www.paradisedata.com.