Paradise P300 User Manual
Page 100

P300H
P300 Series Modem Installation and Operating Handbook
Page 100
Remote M&C: 1:Protocol [Paradise]
2:Intfc [RS485] 3:Baud rate[2400] 4:Addr[123]
Change, Rem-M&C, Configure Menu
6.9.2
Change, Rem-M&C, CONFIGURE Menu
This menu configures the remote M&C port: The options are:
PROTOCOL
This allows selection between
OFF
,
PARADISE/FDC
, and
SA-bus
. Full details of
the remote M&C protocols and messages is provided in the Remote M&C section
in Appendix D.
NOTE: Remote monitoring is possible with the selected protocol if the protocol
is not set to
OFF
. Remote control is only possible if the protocol is not
Off
and
control has been selected as
Remote
on the Change, Remote M&C menu.
INTERFACE
The options available here are RS232 or RS485. RS232 is only usable for a direct
connection between a single device and a PC. RS485 is required when more than
one slave device is connected to the remote M&C bus. Again see the Remote
M&C section for complete details of the electrical interface.
BAUD RATE
The remote M&C Baud Rate is selectable, again see the Remote M&C section
for complete details of suitable Baud Rates for each protocol.
ADDRESS
The bus address must be specified. The valid range for the Paradise / FDC
protocol is 1-255, for the SA-bus protocol the valid range of address is 49 to 111
(31H to 6FH).