Remote M&C: 1:Protocol [Paradise]

2:Intfc [RS485] 3:Baud rate[2400] 4:Addr[123]

Change, Rem-M&C, Configure Menu

6.9.2

Change, Rem-M&C, CONFIGURE Menu

This menu configures the remote M&C port: The options are:

PROTOCOL

This allows selection between

OFF

,

PARADISE/FDC

, and

SA-bus

. Full details of

the remote M&C protocols and messages is provided in the Remote M&C section
in Appendix D.

NOTE: Remote monitoring is possible with the selected protocol if the protocol
is not set to

OFF

. Remote control is only possible if the protocol is not

Off

and

control has been selected as

Remote

on the Change, Remote M&C menu.

INTERFACE

The options available here are RS232 or RS485. RS232 is only usable for a direct
connection between a single device and a PC. RS485 is required when more than
one slave device is connected to the remote M&C bus. Again see the Remote
M&C section for complete details of the electrical interface.

BAUD RATE

The remote M&C Baud Rate is selectable, again see the Remote M&C section
for complete details of suitable Baud Rates for each protocol.

ADDRESS

The bus address must be specified. The valid range for the Paradise / FDC
protocol is 1-255, for the SA-bus protocol the valid range of address is 49 to 111