beautypg.com

Micro mute system – Peavey V12 User Manual

Page 60

background image

p. 60

micro mute system

MIDI Note info received on correct MIDI chan controls Chan mutes(for play-
back from MIDI sequencer)

OFF

No

Note info sent or received

MIDI LOAD Reloads Mute Scenes & Manual Mutes.

Uses Sysex command for dump and load.

MIDI DUMP Dumps all 128 Mute Scenes and all banks of Manual Mutes.

Clear Utilities

CLR SEQ MT Clears all mutes in the 128 Seq Scene memories

CLR SEQ PC Clears (sets to off) all MIDI Pgm Chngs in the 128 Scenes- MIDI
channel set back to default

CLR MM BNK

Clears all Manual Mutes in current Bank

CLR MM ALL Clears all Manual Mutes in all Banks

Show Control

SHOW CTRL NOTE: If Show Control is ON, the V-12 Micro is put into
Show Control Mode.The GO button no longer controls Next Scene to
Active Scene transfer. The Manual Mutes will still function, but the
Sequenced Scene system is disabled (no GO command) along with the
Edit Mode.

Currently, this is the list of MSC data that the V-12 supports (V-12 soft
ware Rev 0.94)

The V-12 only sends MSC data (Note: MSC = MIDI Show Control)

OFF

Normal Console Operation

ON

Lower Display reads "SHOW CTRL "

Upper Display reads "STOP RSM"

Pressing GO sends MIDI Show Ctrl "GO" command

Pressing MUTE sends MSC "STOP" Command

Pressing CHAN sends MSC "RESUME" command

Pressing UP ARROW sends MSC "Standby +"" command

Pressing DOWN ARROW sends MSC "Standby -" command

Pressing RECALL LAST sends MSC "LAST" command

General Controls

BRIGHTNESS

Sets brightness of both Next and Active displays.

REV LEVEL

Show current Software Revision level: (This info correct for

REV 0.94)

MUTE MODE

Sets how many of the possible 13 Mute Scenes can be active

at the same time:

12 Man Mutes, 1 Seq Mute

CUMULATIVE13 of 13 Scenes possible:Any Manual Mutes and Seq Scene

SINGLE_ALLOnly 1 of 13 Scenes possible: 1 of 12 Man Mutes or Seq
Scene