Gas connections

Connecting gas supply piping

1. Remove the top access panel and refer to FIG.’s 7-1 thru 7-4

to pipe gas to the water heater.


a. Install ground joint union for servicing, when

required.

b. On Models 151 - 400 install a manual shutoff valve in

the gas supply piping outside water heater jacket when

required by local codes or utility requirements.

c. In Canada – When using manual main shutoff

valves, it must be identified by the installer.

2. Install sediment trap / drip leg.

GAS SUPPLY

UNION

DRIP LEG

MANUAL

SHUT OFF

VALVE

Figure 7-1 Gas Supply Piping - Models 151 - 200

3. Support piping with hangers, not by the water heater or its

accessories.

SEDIMENT TRAP / DRIP LEG

Figure 7-2 Gas Supply Piping - Models 286 - 400

4. Purge all air from the gas supply piping.

5. Before placing the water heater in operation, check the

water heater and its gas connection for leaks.


a. The appliance must be disconnected from the gas

supply piping system during any pressure testing of

that system at a test pressure in excess of 1/2 PSIG

(3.5 kPa).

b. The appliance must be isolated from the gas supply

piping system by closing a manual shutoff valve

during any pressure testing of the gas supply piping

system at test pressures equal to or less than 1/2 PSIG

(3.5

kPa).

c. The appliance and its gas connection must be leak

tested before placing it in operation.

The gas valve and blower will not support
the weight of the piping. Do not attempt
to support the weight of the piping with
the water heater or its accessories. Failure
to comply could result in severe personal
injury, death, or substantial property
damage.

ƽ WARNING

UNION

(FACTORY INSTALLED)

GAS SUPPLY

SEDIMENT TRAP/

DRIP LEG

MANUAL

SHUTOFF VALVE

(FACTORY SUPPLIED)

Figure 7-3 Gas Supply Piping - Model 501

UNION

(FACTORY INSTALLED)

MANUAL

SHUTOFF VALVE

(FACTORY SUPPLIED)

GAS SUPPLY

SEDIMENT TRAP/

DRIP LEG

Figure 7-4 Gas Supply Piping - Models 601 - 801

44