Lexmark 4059-XXX User Manual
Page 83

Diagnostic Information
2-56
4059-XXX
Configuration 3
A level II fuser board and level II engine board without the solenoid
cable is installed in configuration 3.
Note: Check the fuser envelope conditioner solenoid adjustment as
described in the adjustment section
“Fuser Solenoid Adjustment” on
FRU
Action
1
Engine Board Jumpers
Check to make sure a jumper is
installed between JP1-1 and JP1-2
and also between JP2-1 and JP2-2 on
the engine board.
2
Fuser Envelope Conditioner
Solenoid Fuser Control
Board
The operation of the fuser solenoid
can be observed by removing the
redrive assembly. Check for proper
mechanical operation of the solenoid
and associated hardware, link and so
on. If correct, disconnect the DC fuser
cable from J1 on the fuser control
board and check the resistance of the
solenoid between J1-2 and J1-4 on
connector J1. The resistance
measures between 5 ohms and 10
ohms. If incorrect, disconnect the
solenoid from J4 and check the
resistance of the solenoid between
J4-1 and J4-2. If incorrect, replace the
solenoid assembly. If correct, replace
the fuser control board.
3
Fuser Cable
Check the continuity of the fuser
cable. If the cable does not measure
continuity, replace the cable.