Diagrams, Installation & operation manual, High voltage low voltage 120 vac – Lochinvar KBII-I-O REV C 81 - 286 User Manual

Page 78: Figure 13-2 wiring diagram

background image

Installation & Operation Manual

78

X1-7

ON/OFF

SWITCH

1 2 3 4 5

G

R

R W

R

T

W

BK

Y

BL

BLOWER

-T

HIGH LIMIT SENSOR S1b

OPERATING SENSOR S1a

INLET SENSOR S2

FLUE SENSOR S3a

FLUE SENSOR S3b

INTEGRATED

CONTROL

BK

Y

GAS VALVE
@24VAC

SPARK

ROD

TRANSFORMER

TR2

G

HIGH VOLTAGE SPARK LEAD

CAUTION

FLAME SENSOR

ALARM

CONTACTS

RUN-TIME

CONTACTS

24 VAC LOUVER

RELAY COIL

LOUVER

PROVING SWITCH

GAS PRESSURE

SWITCH

FLOW

SWITCH

TANK

THERMOSTAT

ROOM TSTAT

ZONE CONTROL 3

ROOM TSTAT

ZONE CONTROL 2

ROOM TSTAT

ZONE CONTROL 1

11
12
13
14
15
16
17
18
19
20

SYSTEM

SENSOR

OUTDOOR

SENSOR

TANK

SENSOR

CASCADE

A

B

SHIELD

SHIELD

0-10V

+

-

BMS

IN

0-10V

+

-

SYS PUMP

IN

0-10V

+

-

BLR PUMP

OUT

0-10V

+

-

RATE

OUT

MODBUS

OPTION

A

B

SHIELD

SHIELD

LOW

WATER

CUT-OFF

24 VAC

COM

P/BK

Y

W/R

1
2
3
4
5
6
7
8
9

10

21
22
23
24
25
26
27
28
29
30
31
32

33
34
35
36
37
38
39
40
41
42
43
44

CN7-1
CN7-2
CN7-3
CN7-4

CN5-1
CN5-8
CN5-2
CN5-9
CN5-3

CN5-10
CN5-11

CN5-4
CN5-5

CN5-14
CN5-12

CN5-6

CN5-13

CN5-7

X5-7

X5-16

X5-8

X5-15

X5-9

X5-1

X5-2

X5-10

X5-11

X5-4

X5-12

X5-6

X5-5

X5-13

X5-14

X2-2

X2-1

BK

Notes:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105°C. Exceptions: Replacement high vo ltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead
or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using
diagrams to troubleshoot unit.

WIRING DIAGRAM

LBL20127 REV B

BOX DEPICTS

OPTIONAL ITEMS

X4-7

X4-14

X4-6

X4-13

X4-5

X4-12
X4-11

X4-4
X4-3
X4-8

X4-10

X4-2
X4-9
X4-1

BK
BK
BK
BK

BK
BK
BK
BK
BK

BK
BK
BK
BK

CONNECTION BOARD

CN6

X6

HIGH VOLTAGE

LOW VOLTAGE

120 VAC

X-7

BOX DEPICTS

DUAL SENSOR

SINGLE HOUSING

MODBUS BOARD

MTR-01

CN8

-1

CN8

-2

CN8

-3

X6

-3

X6

-2

X6

-1

X6

-4

X9-1
X9-2
X9-3
X9-4

X4-1
X4-2
X4-3
X4-4

X5-1
X5-2

X1-1
X1-2
X1-3

BK

W

G

R BL G

-T

-T

-T

-T

SHIELD

GROUNDING

JUMPER

O

GY

G

R/BK

W/BK

GY

PR

1 2

G

3

B

E

LL J

U

MP

E

R

AL

AR

M

BEL

L

SI

L

E

N

C

IN

G

SW

IT

C

H

JUNCTION

BOX

DHW
PUMP

BOILER
PUMP

SYSTEM
PUMP

BOX DEPICTS

OPTIONAL

ITEMS

G

G

G

L

GND

N

120V
SUPPLY

X1-3

X1-4

X1-2

X1-5

X1-6

X1-8

X1-1

BK

OR

W

W

W

BR

PR

W

L

N
L

N
L

N

L
N

KB ONLY

AIR PRESSURE
SWITCH

BLOCKED DRAIN
SWITCH

O

P

O/BK

Figure 13-2 Wiring Diagram

13

Diagrams