beautypg.com

Setting regional parameters – Linksys BUSINESS SPA922 User Manual

Page 72

background image

Linksys SPA9x2 Phone Administration Guide

65

Advanced Scripting for Cadences, Call Progress Tones, and Ring Tones

Setting Regional Parameters

Example 1: Dial Tone

• 350@-19,440@-19;10(*/0/1+2)

• Number of Frequencies = 2

• Frequency 1 = 350 Hz at –19 dBm

• Frequency 2 = 440 Hz at –19 dBm

• Number of Cadence Sections = 1

• Cadence Section 1: Section Length = 10 s

• Number of Segments = 1

• Segment 1: On=forever, with Frequencies 1 and 2

• Total Tone Length = 10s

Example 2: Stutter Tone

• 350@-19,440@-19;2(.1/.1/1+2);10(*/0/1+2)

• Number of Frequencies = 2

• Frequency 1 = 350 Hz at –19 dBm

• Frequency 2 = 440 Hz at –19 dBm

• Number of Cadence Sections = 2

• Cadence Section 1: Section Length = 2s

• Number of Segments = 1

• Segment 1: On=0.1s, Off=0.1s with Frequencies 1

and 2

• Cadence Section 2: Section Length = 10s

• Number of Segments = 1

• Segment 1: On=forever, with Frequencies 1 and 2

• Total Tone Length = 12s