SIP Timer Values

Setting SIP Parameters

SIP Timer Values

SIP timer values control transmittal, time-out, delay intervals and so on for SPA9x2 data. Each
value is displayed in seconds.

SIP Timer Notes

Register Retry Enhancements: this feature adds flexibility to the delay timers that are activated
when the SIP REGISTER of a device fails. Timers are selected based on the failure response code
sent by the SIP proxy. Depending on the type of registration failure, either a short timer or a
long timer is activated.

All SIP timer parameters are included in the following table.

Caller ID Header

Select where the SPA9x2 gets its caller ID from:

PAID-RPID-FROM

P-ASSERTED-IDENTITY

REMOTE-PARTY-ID

FROM header

Defaults to PAID-RPID-FROM

Parameter

Description

SIP T1

RFC 3261 T1 value (RTT estimate). Ranges from 0 to 64 seconds.

Defaults to .5 seconds.

SIP T2

RFC 3261 T2 value, which is the maximum retransmit interval for non-
INVITE requests and INVITE responses. Ranges from 0 to 64 seconds.

Defaults to 4 seconds.