INSTALLATION
A-3
A-3
INVERTEC® STT® & STT® II
STANDARD VOLTAGE
INPUT CURRENT AT RATED OUTPUT
200/208/3/50/60 HZ
36/34
200/208/380/400/415/3/50/60 HZ
36/34/20/19/18
TECHNICAL SPECIFICATIONS –Invertec
®
STT
®
II (For Codes 11115 AND 11116)
INPUT- THREE PHASE ONLY
RATED OUTPUT
I
NPUT VOLTAGE
FUSE(SUPER LAG)
INPUT AMPERE
TYPE 75 C
TYPE 75 C
AND FREQUENCY
OR BREAKER
RATING ON
COPPER
COPPER
SIZE
NAMEPLATE
SUPPLY WIRE
GROUND WIRE
IN CONDUIT
IN CONDUIT
AWG (IEC) SIZES
AWG (IEC) SIZES
200/50/60
40
36
208/50/60
40
34
380/50/60
30
20
10 (6 mm2)
10 (6 mm2)
400/50/60
30
19
415/50/60
30
18
HEIGHT
WIDTH
DEPTH
WEIGHT
23.2 in
13.2 in.
24.4 in.
100 lbs.
589 mm
336 mm
620 mm
46 kg
OUTPUT
DUTY CYCLE
AMPS
VOLTS AT RATED AMPS
60% Duty Cycle
225
29
100% Duty Cycle
200
28
CURRENT RANGE
OPEN CIRCUIT VOLTAGE
AUXILIARY POWER
Peak Current 0 - 450 Amps
88 VDC Maximum
115
1
VAC @ 4 Amps
Background 0 - 125 Amps
42 VAC @ 4 Amps
1
115 VAC not present on European Models.
PHYSICAL DIMENSIONS
RECOMMENDED INPUT WIRE AND FUSE SIZES