Lantronix UDS1100 User Manual
Page 75

13: Technical Specifications
UDS1100 User Guide
75
Category
Description
Management
Internal web server
SNMP (read only)
Serial login
Telnet login
DeviceInstaller software
System Software
DeviceInstaller, Windows® 95/98/ME/NT/2000/XP-based configuration software
Com Port Redirector, Windows® 98/NT/2000/XP-based virtual com port software
LEDs Power
10/100 Mb Link
10/100 Activity
Diagnostic
Status
Emissions
FCC Part 15 Subpart B Class A
Radiated Emissions 30MHz – 1000MHz
ICES-003 Issue 4 February 2004 Class A
Radiated Emissions 30MHz – 1000MHz
AS/NZS CISPR 22: 2004 Class A
Radiated Emissions 30MHz – 1000MHz
EN55022: 1998 + A1: 2000 + A2: 2003 Class A Radiated Emissions 30MHz –
1000MHz
VCCI V-3/2005.04 Class A
Radiated Emissions 30MHz – 1000MHz
EN61000-3-2: 2000 Class A
Harmonic Current Emissions
EN61000-3-3: 1995 + A1: 2001
Fluctuations and Flicker
Immunity
EN55024: 1998 +A1: 2001 +A2: 2003
IEC_61000-4-2: 1995
ESD 8KV Air Discharge (Direct), 4KV Contact Discharge
(Direct/Indirect)
IEC_61000-4-3: 1995
Radiated Immunity 3.0V/m, 1KHz AM Sine Wave at 80%
IEC_61000-4-4: 1995
EFT/Burst 1.0KV Power Lines, 0.5KV I/O Lines
IEC_61000-4-5: 1995
Surge Immunity 1.0KV Common Mode, 1.0 KV Differential
Mode
IEC_61000-4-6: 1996
Conducted Immunity 3.0 Vrms, 80% AM Modulated (1KHz)
IEC_61000-4-8: 1993
Magnetic Field Immunity 50Hz 1.0 Arms/m
IEC_61000-4-11: 1994
Voltage Dips and Interrupts (>95%, 0.5 periods), (30%, 25
periods), (>95%, 250 periods)
Isolation
Designed with protections against transients and ESD for use under harsh
environments
Serial Port: 15 KV ESD protection on RS232 and RS422/485 transceivers
Power Input: Up to non-repeated 600 W 10/100 usec pulse protection against transient
over voltages
Ethernet Port: 1500 VAC isolation shielded with shield connected to chassis ground for
signal integrity and ESD protection
Agency Approvals
UL, CSA, FCC, CE, TUV, CTick, VCCI