Assigning raid levels, Configuring logical drives, Assigning raid levels configuring logical drives – LSI MegaRAID Express 500 User Manual
Page 59
Chapter 5 Configuring MegaRAID Express 500
45
Assigning RAID Levels
Only one RAID level can be assigned to each logical drive. The drives required per RAID
level is:
RAID
Level
Minimum Number of
Physical Drives
Maximum Number of Physical
Drives
0
1
15
1
2
2
3
3
15
5
3
15
10
4
14
30
6
15
50
6
15
Note:
The maximum number of physical drives supported by the controller is 15.
Configuring Logical Drives
After you have installed the MegaRAID Express 500 controller in the server and have
attached all physical disk drives, perform the following actions to prepare a RAID disk
array:
Step
Action
1
Optimize the MegaRAID Express 500 controller options for your system.
See Chapter 6 for additional information.
2
Perform a low-level format the SCSI drives that will be included in the
array and the drives to be used for hot spares.
3
Press
4
Define and configure one or more logical drives. Select Easy Configuration
in MegaRAID Manager or select New Configuration to customize the
RAID array.
5
Create and configure one or more system drives (logical drives). Select the
RAID level, cache policy, read policy, and write policy.
6
Save the configuration.
7
Initialize the system drives. After initialization, you can install the
operating system.