beautypg.com

Menu system – Kenwood XXV-01D User Manual

Page 42

background image

42

|

English

Menu system

In Standby mode

G-Analyzer Calibration setup

G-Analyzer requires calibration for horizontal
acceleration and braking.

• Detection of horizontal and straight directions should

be done at horizontal location going straight.

1

Park the vehicle in a horizontal location

2

Select G-Analyzer Calibration setup mode

Push the Control knob towards [

4] or

[

¢].

Select the "G-Calibration" display.

3

Enter G-Analyzer Calibration setup mode

Press the Control knob for at least 1 second.
"Stop" is displayed.

4

Start Calibration of horizontal direction

Press the Control knob.
Once "Move Forward" appears on the display, the
vehicle must be advanced.

5

Start Calibration of straight direction

When the vehicle is driven in the straight
direction, calibration of straight direction
automatically starts.

• In order to operate the detection of straight direction.

When the Calibration is finished, "Calibration OK"
is displayed.

• If you fail to complete the calibraton, "No Calibration"

is displayed. In such a case, repeat steps 1 thru 6.

6

Exit G-Analyzer Calibration setup mode

Press the [MENU] button.

G-Analyzer Stop Watch

The control of stop watch can be started by G-
Analyzer function.

• Do not use G-Analyzer stop watch on the Public roads.

1

Select G-Analyzer Stop Watch mode

Push the Control knob towards [

4] or

[

¢].

Select the "Stop Watch" display.

2

Enter G-Analyzer Stop Watch mode

Press the Control knob for at least 1 second.
"Stop" is displayed.

3

Enter Counter Ready mode

Press the Control knob.
"Ready" is displayed.

4

Start Count

When G in the vertical direction is detected
during the travel, the count automatically starts.
"Running" is displayed.

• You can also start the counter by pressing the Control

knob.

5

Stop Count

Press the Control knob.
"Stop" is displayed.

• The control will start again when you accelerate or

press the Control knob.
Do the operation after step3.

When you Reset the Count
(While "Stop" is displayed)

Press the Control knob for at least 2 seconds.

• You can reset of count when the count is stopped.

6

Exit G-Analyzer Stop Watch mode

Press the [MENU] button.

• When "Running" is displayed (counted), the count is

continued even though G-Analyzer Stop Watch mode
is finished. If you want to stop the count, enter the
menu mode then press the control knob.

• When Power off (ex; ACC OFF) while counting, the

value of 1 second or less will be "00".