Appendix B Host Computer Interface

B-4

H5: Protocol logic

The factory default setting is 0.

H6: Buffer nearly-full threshold
This is a percentage from 0 to 99. The factory default setting
is 90.

H7: Buffer nearly-empty threshold
This is a percentage from 0 to 99. The factory setting is 70.
The factory default settings of the buffer nearly-full and near-
ly-empty thresholds (H6 and H7) are subject to change with-
out notification.

The gap between the nearly-full and nearly-empty thresholds
allows the computer to send a fairly large amount of data in
a continuous stream.

H8: Received-data buffer size
This is the size of the input buffer, specified in units of 10
Kbytes. The factory-set value is 6, meaning 60 Kbytes.

The PRESCRIBE FRPO D0 command provides control over
XON/XOFF operation when an error occurs on the serial in-
terface. The following table summarizes the error status cor-
responding to different D0 values.

Make sure that the RS-232C cable is wired correctly. The ca-
ble must be a null modem cable; that is, one in which pin 2 on
either end of the cable is connected to pin 3 on the other end.
You cannot use a straight cable such as IBM communication
adapter cable type 1502067 unless you purchase a null mo-
dem adapter.

Remove the plastic cover from the printer end of the
cable.

Next to each of the wires inside the cable is a bare
shield wire. Solder all these shield wires together
into a single bundle.

Using a section of flat wire about 3 mm wide and 15
mm long, connect the bundle of shield wires to the
metal facing of the connector. Check that the solder
connections are secure.

Desolder wires 2 and 3, then resolder them in
crossed configuration. Solder wire 2 to pin 3 and
wire 3 to pin 2. Cover the solder joints with ther-

mofit tube.

Cut wires 4, 5, 6, and 20.

Solder wires 5 and 6 together and connect them to
pin 20. Cover the solder joints with a thermofit tube.
Leave wire 4 unconnected.

Tape all remaining loose ends, or seal them with a
thermofit tube.

Attach the plastic cover back on.

Check that the power of both the printer and the computer is
switched off.

Discharge yourself of static electricity by touching a
metal object such as a doorknob.

Remove the plastie cap from the printer’s RS-232C
interface connector.

Plug the printer end of the RS-232C interface cable
into the printer’s RS-232C connector and screw it in
place.

Plug the other end of the cable into the computer’s
RS-232C interface connector.

Switch on the printer’s power.

Parameter value

Meaning

0

Combination of 1 and 3 below

1

DTR/DSR, positive logic

2

DTR, negative logic

3

XON/XOFF

4

ETX/ACK

5

XON/XOFF recognized only as protocol

Table B-6

4.1 PRESCRIBE FRPO D0 command

Timing of XON transfer to host
while Ready or Waiting

Serial interface error

Error
not resolved

Error
resolved

XON sent every 3 to 5 seconds

D0=0
(default)

D0=1

XON not sent

D0=10

D0=11

Table B-7

5. RS-232C Cable Connection

5.1 Obtain a Suitable RS-232C Cable

5.2 Connecting the Printer to the Computer

1

2

3

4

5

6

7

8

1

2

3

4

5

This manual is related to the following products: