To connect the optical cables, Table 2-1 – Sun Microsystems Sun StorageTek SG-XPCIE20FC-NEM-Z User Manual
Page 28
12
Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008
▼ To Connect the Optical Cables
Note –
The NEM does not allow normal data transmission on an optical link unless
it is connected to another similar or compatible Fibre Channel (FC) product (that is,
multimode to multimode).
Use multimode fiber-optic cable, intended for short-wave lasers, that adheres to the
specifications in
.
Follow these steps when connecting the optical cables:
1. Connect each fiber-optic cable to an LC connector on the NEM (see
The ports are numbered 0-9 right-to-left as viewed from the back of the chassis.
Each NIC has two external network ports. For each pair of external ports (for
each blade), the top is port 0 and the bottom is port 1.
TABLE 2-1
Optical Cable Specifications
Fiber-Optic Cable
Maximum Length
Minimum Length
Connector
62.5/125
µ
m
(multimode)
300 meters at 1.0625 Gbps
150 meters at 2.125 Gbps
70 meters at 4.25 Gbps
2 meters
LC
50/125
µ
m
(multimode)
500 meters at 1.0625 Gbps
300 meters at 2.125 Gbps
150 meters at 4.25 Gbps
2 meters
LC