MODEL
SP-M275
SP-M305
Panel
Size
0.63 inches 3P LCD
Resolution
XGA (1024 x 768)
Aspect ratio
4 : 3
Power
Power Consumption
280 W
(Standby : under 1W)
(Standby : under 1W)
295 W
V
0
4
2
~
0
0
1
e
g
a
tl
o
V
AC, 50/60Hz
Lamp
Power Consumption
230 W
Life Time
3,000 Hours (Eco : 5,000 Hours )
Dimension
279 x 229 x 79 mm / 10.98 x 9.02 x 3.11 inches
Weight
2.7 Kg / 6.0 lbs
Key Features
0
0
7
,
2
s
s
e
n
t
h
g
ir
B
ANSI
3,000 ANSI
Contrast
2000 : 1 (Only in Dynamic of picture mode)
Projection Range
1 m ~ 14 m / 39.37 inches ~ 551.18 inches
Network
Wired LAN Port (RJ45), 10 Mbps
Zoom Adjustment
Manual
Focus Adjustment
Manual
Screen Size (Diagonal)
Diagonal 30 inches ~ 400 inches
Lens
F = 1.7 ~ 1.87, f = 19.2 mm ~ 23 mm
Zoom Ratio
1 : 1.2
Input signal
D-Sub 15p
Analog RGB, analog YPbPr
HDMI
Digital RGB, digital YPbPr
RCA x 1
Composite video
Media Play
USB supports
Speaker
7 W (Mono)
User Environ-
ment
Noise
Eco : 31 dB, Bright : 35 dB
Keystone
Auto: Vertical(±20°) / Manual: Vertical (±20°)
Temperature and Humidity
Operating : Temperature 41 °F ~ 95 °F (5 °C ~ 35 °C),
Humidity : 20 % ~ 80 % (Non-condensing)
Storage : Temperature 14 °F ~ 140 °F (-10 °C ~ 60 °C),
Humidity : 10 % ~ 90 % (Non-condensing)
Class B (Information Communication equipment for residential use)
This device is registered for EMC requirements for home use (Class B). It can be used in all areas. (Class B equipment