Handling of parity errors (perr) – Sun Microsystems Sun Fire X4240 User Manual
Page 69
Appendix D
Error Handling
59
Handling of Parity Errors (PERR)
This section lists facts and considerations about how the server handles parity errors
(PERR).
■
The handling of parity errors works through NMIs.
■
During BIOS POST, the NMI is logged in the DMI and the SP SEL. See the
following example command and output:
■
FIGURE D-3
shows an example of a DMI log screen from BIOS Setup Page, with a
parity error.
[root@d-mpk12-53-238 root]# ipmitool -H 129.146.53.95 -U root -P changeme -I lan
sel list -v
SEL Record ID
: 0100
Record Type
: 00
Timestamp
: 01/10/2002 20:16:16
Generator ID
: 0001
EvM Revision
: 04
Sensor Type
: Critical Interrupt
Sensor Number
: 00
Event Type
: Sensor-specific Discrete
Event Direction
: Assertion Event
Event Data
: 04ff00
Description
: PCI PERR