Error handling, Handling of uncorrectable errors – Sun Microsystems Sun Fire X4240 User Manual
Page 63
53
A P P E N D I X
D
Error Handling
This appendix contains information about how the servers process and log errors.
See the following sections:
■
“Handling of Uncorrectable Errors” on page 53
■
“Handling of Correctable Errors” on page 56
■
“Handling of Parity Errors (PERR)” on page 59
■
“Handling of System Errors (SERR)” on page 61
■
“Handling Mismatching Processors” on page 63
■
“Hardware Error Handling Summary” on page 64
Handling of Uncorrectable Errors
This section lists facts and considerations about how the server handles
uncorrectable errors.
Note –
The BIOS ChipKill feature must be disabled if you are testing for failures of
multiple bits within a DRAM (ChipKill corrects for the failure of a four-bit wide
DRAM).
■
The BIOS logs the error to the SP system event log (SEL) through the board
management controller (BMC).
■
The SP's SEL is updated with the failing DIMM pair's particular bank address.
■
The system reboots.
■
The BIOS logs the error in DMI.