SPECIFICATIONS

Signal format

: Based on NTSC color signal standard (MPX-CD4)

Based on NTSC B/W signal standard (MPX-MD4)

Camera signal input synchronization

: Asynchronous

Camera input terminals (IN)

: VS/VBS, 1.0 Vp-p/75

, BNC connector x 4

Camera output terminals (OUT)

: Throughput of each input, 1.0 Vp-p/75

, BNC connector x 4

VCR input terminal (VCR IN)

Composite input

: VS/VBS, 1.0 Vp-p/75

, BNC connector x 1

S-VHS input terminal (S-VHS VCR IN)

: Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD4 only)

Y signal: 1.0 Vp-p/75

, unbalanced, synchronous; C signal: 0.286 Vp-p/75

,

unbalanced

VCR output terminal (VCR OUT)

Composite output

: VS/VBS, 1.0 Vp-p/75

, BNC connector x 1

S-VHS output terminal (S-VHS VCR
OUT)

: Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD4 only)

Y signal: 1.0 Vp-p/75

, unbalanced, synchronous; C signal: 0.286 Vp-p/75

,

unbalanced

Monitor 1 output terminal (MONITOR OUT 1) : VS/VBS, 1.0 Vp-p/75

, BNC connector x 1

Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD4 only)
Y signal: 1.0 Vp-p/75

, unbalanced, synchronous; C signal: 0.286 Vp-p/75

,

unbalanced
Camera live picture or VCR playback picture signal output: full screen, sequential
display, 4 divisions split screen

Monitor 2 output terminal (MONITOR OUT 2) : VS/VBS, 1.0 Vp-p/75

, BNC connector x 1

Camera live picture signal output: full screen (can be set in (MONITOR SET) menu
to display the same image as monitor 1)

Control terminal (CONTROL)

Alarm input (1 – 4)

: No voltage, make-contact switch input x 4 (Low input)

Remote input (R1, R2)

: 2-wire type with resistance-based identification system

Alarm output (A)

: DC 5 V, 5.7 k

(Low output)

Switching input (S)

: Low input, for input signal from SW OUT of timelapse VCR/real time recorder (as

per this manufacturer specifications)

RS-232C terminal

: 9-pin D-SUB

Full screen sequence timing

: Available in full screen, 8 settings (1, 2, 3, 4, 5, 10, 20, 30 sec.)

Monitor on-screen display

: Title (up to 10 characters), date, time selectable

Menu settings

: 9 menus: Language, Clock, Title, Alarm, Sensor, Timer, Display, VCR, Alarm data

Alarm sensor

: Internal, 4 channel (each camera input, selectable)

Back-up function

: Back-up for up to 30 days of the clock settings after connected for 30 hours

continuously

Operations

Still

: Available for camera live or VCR playback in 4 divisions split screen, full screen and

zoomed in picture
Can be set using a menu to operate automatically when there is an alarm trigger

Zoom

: Available for camera live or VCR playback in 4 divisions split screen, full screen and

frozen picture

In full screen mode can switch from frozen to zoomed in picture

Power

: AC 120 V, 60 Hz

Consumption

: 19 W (MPX-CD4), 14 W (MPX-MD4)

Operating environment

: Temperature: 5 to 40˚C, Humidity: 10 to 80%

Dimensions

: 420 (W) x 44 (H) x 325 (D) mm

Weight

: Approx. 3.4 kg

Products are subject to change in design and specifications without notice and without incurring any obligation.

L8FH5/US (MPX-CD4 GB) 1999. 6. 4