Information about hardware, Hardware issues and workarounds, Sun crypto accelerator 6000 cards – Siemens SPARC ENTERPRISE M8000 User Manual
Page 15
Information
about
Hardware
7
Information about Hardware
This section describes the special instructions and the issues about the SPARC
Enterprise M8000/M9000 servers hardware.
■
Hardware Issues and Workarounds
Hardware Issues and Workarounds
lists known hardware issues and possible workarounds.
Sun Crypto Accelerator 6000 Cards
If you are not using the correct version of the Sun Crypto Accelerator (SCA) 6000
card driver, hot-plug operations on SCA 6000 cards can cause Sun SPARC Enterprise
M4000/M5000 servers to panic or hang. Version 1.1 of the SCA6000 driver and
firmware supports hot-plug operations after the required bootstrap firmware
upgrade has been performed. Version 1.0 of the SCA6000 driver does not support
hot-plug and should not be used.
TABLE 2
Hardware Issues and Workarounds
CR ID
Description
Workaround
6433420
The domain console might display a Mailbox
timeout or IOCB interrupt timeout error during
boot.
Issue a reset -all command from the
OpenBoot PROM (OK) prompt and reboot.
6557379
Power cables are not redundant on single
power feed servers without the dual power
feed option.
On servers that have single power feed, all
power cables must be connected and powered
on at all times.