4.2.2.3. Proper System Shutdown
The BCU/CAL must be shut down in an orderly fashion prior to a system reboot. This procedure essentially disconnects
the link to the IMC CAM, gracefully closes any open files (especially significant for the BCU), and secures the hard drive file
system. The proper way to shut down the BCU/CAL can be executed from either the "root" or "admin" accounts. This
procedure is shown by way of example.
USER INFORMATION: Invoke the BCS program.
pSH+> bcs
Welcome to the BCU-CAL Configuration Service (BCS)
System Administrator privilege acknowledged.
USER INFORMATION: The BCS "halt" command performs the proper shutdown procedure.
BCS> halt
USER INFORMATION: Wait at least 2 minutes from issuing the "halt" command, then exit BCS.
BCS> exit
pSH+>
At this point, the BCU/CAL may be powered-down, or rebooted, without concern for disk data integrity. Under extreme
(i.e., panic) circumstances, the "root" user can force an immediate reboot by entering "reboot -h" at the pSH+> prompt, either