USER INFORMATION: Enter “ls” to observe the root level directory files and subdirectories which were created
during the software installation process.

pSH+> ls
BITMAP.SYS

backup

etc

mnt

var

FLIST.SYS

bin

export

rar

LOADER.SX

cdr

loads

tmp

activity

cnfg

log

usr

USER INFORMATION: The following example shows the configuration files for the unit. The .BIN files were
created during the software installation process.

pSH+> cd cnfg

pSH+> ls -als

total 41

2 -rwxrwxrwx 1 root 622 Feb 01 1994 10:45 CAL.DAT

2 -rwxrwxrwx 1 root 892 Feb 01 1994 10:45 IP.DAT

2 -rwxrwxrwx 1 root 568 Feb 01 1994 10:47 SYSTEM.BIN

1 -rwxrwxrwx 1 root 131072 Feb 01 1994 10:47 UNIT.BIN

33 -rwxrwxrwx 1 root 16384 Feb 01 1994 10:47 GROUP.BIN

USER ACTION: Two system parameters may need to be set. If the BCU/CAL is operating in a Multi-
Node/StarGate configuration, the IMC NIM slot number needs to be defined. If the BCU/CAL service area
(IMC) has a Jessica interconnect system installed, the IMC PIM slot number needs to be defined. These
parameters must be set appropriately for the BCU to correctly provide billing for calls involving these “sites” (i.e.,
StarGate or Jessica). They are required by the CAL to simulate secondary drops from the site(s) it is providing
service for. If the parameter (NIM or PIM slot) does not apply, it should be set to zero (default value).

These parameters are defined using the BCU/CAL Configuration Service (BCS) program. BCS is discussed in detail in

LBI-38967. The following example is provided for reference to get the BCU set up and running as quickly as possible.

PREREQUISITE

1.

Obtain the IMC slot number of the NIM and PIM modules, if any.

2.

If not already logged into the BCU/CAL, log in under the "root" account as previously discussed. Enter the
following commands at the indicated prompts.

USER INFORMATION: Entering "bcs" invokes the BCS program.

pSH+> bcs

Welcome to the BCU-CAL Configuration Service (BCS)

System Administrator privilege acknowledged.

USER INFORMATION: Entering "show system" displays the default system parameters that were initialized
during the initial software installation.

BCS> show system
Default unit pseudo hangtime = 10
Default group pseudo hangtime = 10
Default group billing mode = Bill callee
Data call pseudo hangtime = 10
Data call billing = On
Phone digits mandatory = Off
CDR maximum file records = 1024
CDR sequence wrapping = On