Page 41

780 SERIES

13.4 Panel displays SN2

Open or shorted sensor (heater disabled). The temperature

sensor is not functioning. Your authorized dealer must repair this.

13.5 Panel displays FL1 or FL2

A flashing “FL1” display means the flow switch is

malfunctioning open, the circulation pump’s filter cartridge is

excessively dirty, or an “air lock” condition has occurred at the

circulation pump intake. A flashing “FL2” display means the

flow switch is malfunctioning closed.

This error will cause the heater to deactivate. The main

pump #1 may also deactivate.

This problem is caused by an interruption in water flow from an

excessively dirty filter cartridge, an “air lock” condition at the pump

intake, or by a malfunctioning flow switch.

To Correct Condition:

1. Verify water level is above all jets and below lowest pillow.

Add water if necessary.

2. Check for clogged/excessively dirty filter cartridge. See

Section 11.1 (pages 31-32).

3. Purge “air lock” from circulation pump intake by removing the filter

cartridge. Hold your garden hose over the filter wall fitting (with

grate) using a rag as a seal around hose end, then ask a helper to

turn on water for 30 seconds, then turn off. Reinstall filter cartridge

and check spa. See Section 11.1 (pages 31-32).

4. If the circulation pump is not running, turn power off at the main

breaker, then turn power back on. This will reset the circulation pump

priming cycle. Once the pump is primed, the error should clear.

5. If problem persists, contact your authorized dealer.

13.6 Panel displays COL

Cool Condition - Temperature has dropped 20°F (11°C) below

the current set temperature. The pump and heater have been

activated to bring the temperature to within 15°F (8°C) of the set

temperature. No corrective action is required (page 30).

Note: During cold periods, you may consider increasing the number of

filtration cycles.

13.7 Panel displays ICE

Freeze Protection - A potential freeze condition has been

detected. No action is required. Main pump will operate to

circulate warm water through the plumbing until the spa is out of

danger.