780 SERIES

6.0 Electrical Wiring Instructions

IMPORTANT NOTICE: The electrical wiring of this spa

must meet the requirements of the National Electrical

Code (NEC) and any applicable state or local codes.

The electrical circuit must be installed by a qualified

electrician and approved by a local building/electrical inspection

authority.

1.

Convertible 120/240v Powered dover Models Only:

!

dANGER:

TO dECREASE THE RISK OF SHOCK,

PROdUCT dAMAGE OR ELECTRICAL FIRE.

120v “Plug-in” Operation: This spa must operate on the

supplied 10 foot (3m) 120V GFCI cord at its original length or

must be hard-wired for longer runs.

NEvER USE AN EXTENSION

CORd FOR ANY REASON!

• Convertible 120/240V Heater Operation: the included 120V GFCI

cord must be discarded for 240V heater operation. This spa must

be hard-wired. Supplying power to either configuration above

which is not in accordance with these instructions will void both

the independent testing agency listing and the manufacturer’s

warranty.

Export 2-Pump Certa/Chelsee/Hamilton Models (50 Hz)

230v/20A*

230v/30A**

230v/40A***

Voltage:

230 VAC

230 VAC

230 VAC

# of Wires:

3

3

3

Frequency:

50 Hz

50 Hz

50 Hz

Current Draw:

15A

23A

29A

Circuit Breaker:

20A*

30A**

40A***

* In 20A configuration, the heater

will not operate while either jets pump is

running in high speed.

This is the factory setting. Note: pump 2 runs

only in high speed.

** In 30A configuration, the heater

will not operate while both jets pumps

are running in high speed.

Note: pump 2 runs only in high speed.

*** In 40A configuration, the heater

will operate while both jets pump are

running in high speed.