13.0 Error Conditions/Error Messages

There are a number of unique functions designed into your spa to

protect it from damage and/or aid in troubleshooting. Refer to Sections

13.1-13.8 below for a listing of all possible error messages and their

meanings.

13.1 Summer Logic

When the actual spa water temperature reaches up to 2°F

(1°C) above the set temperature, the spa goes into

“summer logic.” The circulation pump will turn off

automatically to avoid adding additional heat to the water,

eventually creating an overheat condition. This setting is not

user-programmable.

Note: The summer logic does not take effect until the spa water

temperature reaches 95°F (35°C). This condition is more likely in

excessively hot weather. Remember, the spa’s ability to cool is directly

affected by the ambient temperature. An excessively hot ambient

temperature may prevent the spa from cooling down because it’s

fully insulated construction is designed to retain heat and to minimize

operating costs.

13.2 Overheat Condition

WARNING: RISK OF HYPERTHERMIA (OvER-HEATING)

CAUSING SEvERE INjURY, bURNS, OR WELTS.

!

dO NOT ENTER SPA WATER! Water is too hot. Overheat

protection. Heater is deactivated. Spa water temperature is

above acceptable limits.

When the actual water temperature

is approximately 2°F (1°C) above the set temperature, the

circulation pump will stop operating to reduce (frictional) heating. To

correct condition, remove spa cover to speed cooling.

(CAUTION!

Never leave spa uncovered when children are present!) If condition

persists, contact your authorized Sundance dealer.

13.3 Panel displays SN1

Open sensor (heater is disabled) or shorted sensor (spa is

deactivated). The high-limit temperature sensor is not

functioning. Your authorized dealer must repair this.