780 SERIES
North American Certa/Chelsee/Hamilton 2-Pump Models (60 Hz)
240v/40A*
240v/50A**
240v/60A***
Voltage:
240 VAC
240 VAC
240 VAC
# of Wires:
3
3
3
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
26A
36A
45A
Circuit Breaker:
40A*, 2-Pole
50A**, 2-Pole
60A***, 2-Pole
*
In 40A configuration, the heater
will not operate while either jets pump is
running in high speed.
Note: pump 2 runs only in high speed.
** In 50A configuration, the heater
will not operate while both jets pumps
are running in high speed.
Note: pump 2 runs only in high speed. This
is the factory setting.
*** In 60A configuration, the heater
will operate while both jets pumps are
running in high speed.
Note: pump 2 runs only in high speed.
5.2
Export 50 Hz Power Options
Export 1-Pump Camden/dover Models (50 Hz)
230v/20A*
230v/30A**
Voltage:
230 VAC
230 VAC
# of Wires:
3
3
Frequency:
50 Hz
50 Hz
Current Draw:
15A
21A
Circuit Breaker:
20A*
30A**
* In the 20A configuration, the heater
will not operate while the jets pump
is running in high speed.
This is the factory setting.
** In the 30A configuration, the heater
will operate while the jets pump is
running in high speed.