beautypg.com

1 north american 60 hz power options, North american 60 hz power options – Sundance Spas CAMDEN 780 User Manual

Page 16

background image

Page 12

780 SERIES

5.1

North American 60 Hz Power Options

North American dover Convertible Models (60 Hz)

120v/15A*

240v/30A*

240v/40A**

Voltage:

120 VAC

240 VAC

240 VAC

# of Wires:

3 (15A GFCI

Cord, US Models

Only*)

4 (Hard Wired

Only)

4 (Hard Wired

Only)

Frequency:

60 Hz

60 Hz

60 Hz

Current Draw:

12A

21A

30A

Circuit Breaker:

15A*, 1-Pole

30A*, 2-Pole

40A**, 2-Pole

CAUTION (For 4-wire, 240 vAC Heater Operation): Move the red wire on

the main terminal strip (TB1) from position #1 to position #3. Make certain

wires are connected exactly as shown in Figure D (page 17) before applying

power. Failure to do so will result in damage to the circuit board and/or

related components and void the manufacturer’s warranty.

* In the 15A and 30A configuration, the heater

will not operate at the same

time as the high-speed jets pump.

The factory setting is 120v/15A.

Note: all Canadian spas must be hard wired (120 vAC or 240 vAC) per

CSA Canadian standards (page 8).

** If the spa is to be operated on 40A service, remove the jumper JP1 #1-2

on the circuit board to allow the heater to operate at the same time as the

high-speed jets pump (page 44).

North American 1-Pump Camden Model (60 Hz)

240v/40A*

240v/50A**

Voltage:

240 VAC

240 VAC

# of Wires:

3

3

Frequency:

60 Hz

60 Hz

Current Draw:

26A

36A

Circuit Breaker:

40A*, 2-Pole

50A**, 2-Pole

* In the 40A configuration, the heater

will not operate while the jets pump

is running in high speed.

** In the 50A configuration, the heater

will operate while the jets pump is

running in high speed.

This is the factory setting.