1 north american 60 hz power options, North american 60 hz power options – Sundance Spas CAMDEN 780 User Manual
Page 16
Page 12
780 SERIES
5.1
North American 60 Hz Power Options
North American dover Convertible Models (60 Hz)
120v/15A*
240v/30A*
240v/40A**
Voltage:
120 VAC
240 VAC
240 VAC
# of Wires:
3 (15A GFCI
Cord, US Models
Only*)
4 (Hard Wired
Only)
4 (Hard Wired
Only)
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
12A
21A
30A
Circuit Breaker:
15A*, 1-Pole
30A*, 2-Pole
40A**, 2-Pole
CAUTION (For 4-wire, 240 vAC Heater Operation): Move the red wire on
the main terminal strip (TB1) from position #1 to position #3. Make certain
wires are connected exactly as shown in Figure D (page 17) before applying
power. Failure to do so will result in damage to the circuit board and/or
related components and void the manufacturer’s warranty.
* In the 15A and 30A configuration, the heater
will not operate at the same
time as the high-speed jets pump.
The factory setting is 120v/15A.
Note: all Canadian spas must be hard wired (120 vAC or 240 vAC) per
CSA Canadian standards (page 8).
** If the spa is to be operated on 40A service, remove the jumper JP1 #1-2
on the circuit board to allow the heater to operate at the same time as the
high-speed jets pump (page 44).
North American 1-Pump Camden Model (60 Hz)
240v/40A*
240v/50A**
Voltage:
240 VAC
240 VAC
# of Wires:
3
3
Frequency:
60 Hz
60 Hz
Current Draw:
26A
36A
Circuit Breaker:
40A*, 2-Pole
50A**, 2-Pole
* In the 40A configuration, the heater
will not operate while the jets pump
is running in high speed.
** In the 50A configuration, the heater
will operate while the jets pump is
running in high speed.
This is the factory setting.